Conductivity & TDS Controller ATS-X1000-BW1


INTRODUCTION
ATS-X1000-BW1 is an ARM processor based industrial controller which is used to analyze and control Conductivity/ TDS parameter in various water applications. It provides set point values and relay for HighLow signal. Only one point calibration is required, or user can operate the controller just by entering the K-Factor. Simple to control through its 6-button control panel. The backlit LCD contrast and brightness can be adjusted to user requirement. Provide logging function can save parameters values with respect to time. Password protection feature is added for settings and process safety.

APPLICATIONS
• REVERSE OSMOSIS
• BOILER WATER
• COOLING WATER
• CLOSED LOOP SYSTEM
• DRINKING WATER
• TEXTILES CHEMICALS
• WASTE WATER
















×

Description


INTRODUCTION
CD1000 Series Controller is a microprocessor-based controller used to analyze and control Conductivity / TDS parameter in various water applications. CD 1000 provides set point values and relay for High-Low signal. Usually it doesn’t require any calibration but only 1-point calibration if required.

CD 1000 series is simple to control through its 6-button control panel. The backlit LCD contrast can be adjusted to user requirement. Provided logging function can save parameters values with respect to time.

APPLICATIONS
• REVERSE OSMOSIS
• BOILER WATER
• COOLING WATER
• CLOSED LOOP SYSTEM
• DRINKING WATER
• TEXTILES CHEMICALS
• WASTE WATER

×
Specifications Descriptions
Measuring Range (Conductivity) 0.00 μS/cm – 10.00 S/cm, 0.01 μS/cm resolution, +/- 0.5% accuracy
Measuring Range (TDS) 0.00 – 10,000 PPT, 0.01 PPM resolution, +/- 0.5% accuracy
Measuring Range (Temperature) 0.0-200.0°C, 0.1°C resolution, Linear Coefficient +/- 1.0°C accuracy
Clock Internal Clock, 24 Hr format, +/- 1 min / month accuracy
SD Card (Optional) ICan save multiple values in SD Card, user can save values for up to 5 years with Data Read, Data Rate, Format value
Calibration Mode One point calibration is required, or user can operate the controller just by entering the K-Factor
Analog Output 1 4 – 20mA corresponding to conductivity, +/- 0.001mA accuracy, 0.001mA resolution, maximum load 500Ω
Analog Output 2* 4 – 20 mA corresponding to temperature, +/- 0.001mA accuracy, 0.001mA resolution, maximum load 500Ω
Cell Constants 2 – pole Electrode: 0.01 – 20 /cm fixed, 0.001 – 19.99/cm freely selectable (user defined) 4 – Pole Electrode for High conductivity measurements
Relays 1 (HI) – 250 VAC, 0.5A – On/Off Programmable
2 (LO) – 250 VAC, 0.5A – On/Off Programmable
Relay function with Dead Band
Display Large Graphical LCD (128 × 64) with adjustable Contrast and Adjustable Brightness
Dimensions (Volume Based) L x W x D (113.5mm x 113.5mm x 83mm)
Panel Cutout Size L × W (93mm × 93mm)
Temperature Compensation* Linear Temperature Compensation through-out the sensor range 2 – wire & 3 – wire Pt1000 RTD auto/ manual
Weight (Assembly) Approximately ~ 255 Grams
Modbus RTU / Wi-Fi (Optional) Modbus RTU and Wi-Fi communication with any device and connect multiple devices with device ID and parity settings (AT system Software will be required)
IP Class Protection IP 65 (In Panel Mount Installation)

*Temperature analog output feature in X1000-BW1 will be added upon user’s request


×